KE3700 CT Telco Loop Qualifier

KE3700 CT for DC and AC noise analysis with digital multimeter function, TDR function for cable troubleshooting and measurements up to 31 MHz. With filter for ADSL, VDSL and SHDSL.

  • Spectrum analysis, impedance, reflection loss, LCL unbalance loss and NEXT, receive level (graph.), signal level transmitter, broadband and pulse noise
  • Symmetry, resistance and capacitance
  • Voltage AC/DC incl. AC Frequency
  • Insulation measurement with 8 V or 100 V
  • RFL resistance fault localization according to Murray and Küpfmüller
  • TDR detects and locates cable faults with xTalk measurements
  • Automated, freely editable test sequences
  • Simplification and acceleration of the measuring application through the KE905 Remote included in the scope of delivery
  • Storage and evaluation of measurement data
Login to see prices
SKU: 0.49840-CT Categories: ,

Overview

KE3700 CT Telco Loop Qualifier is a line qualifier up to 31 MHz for interference analysis in the DC and AC range with Telcomultimeter function, TDR for cable troubleshooting and measurements for qualification up to 31 MHz. The device allows the qualification of a copper twisted pair on the service to be transmitted. Predefined or manually editable filters are available for xDSL or telephony services in the frequency range up to 31 MHz.

Manual and automatable test sequences in combination with the KE905 Remote electronic remote line switch are available to the user to simplify measurement tasks. Bluetooth, QR code and the supplied KE Manager software allow flexible use with regard to documentation of measurement results or data transmission to electronic order processing systems.

The various xDSL systems (Digital Subscriber Line Systems) available on the market have the task of meeting the requirements of fast data transmission for fast Internet access, remote LAN access, interactive media applications, etc. The system can also be used for the transmission of data to other electronic order processing systems. The "x" in the name xDSL indicates the different types of DSL technologies that use conventional copper lines for fast data transmission. The xDSL modems use higher frequencies and can therefore achieve a higher data transmission speed, although they are the same wire pairs used for analog telephony (POTS) and ISDN.

The main advantage of xDSL is the elimination of installation costs for new cables. The maximum allowed cable length and the maximum achievable data transmission speed depend on the characteristics of the cable. Before installing an xDSL modem, check that the properties and quality of the selected wire pair meet the requirements of the intended system.

KE3700 CT– Features
- Error detection with Telco Multimeter functions
- Measurement of all parameters required for the qualification of subscriber lines from ADSL to VDSL2
- Automatic test programs give detailed measurement results
- Parameter editor for changing system and cable parameters
- Interface for data transmission to a PC
- Fault location with TDR up to 6 km
- Remote switching with the optional KE905 remote unit

Measuring modes DMM
- Voltage
- isolation
- resistor
- loop resistance
- loop impedance symmetry
- capacity
- capacitance symmetry
- LCL at 1 MHz
- Automatic line analysis (individually configurable)
- lead resistance
- stream
- Signature and PPE recognition (Telekom)

Measurement modes Qualification
- impedance
- return loss
- Unbalanced attenuation (LCL)
- NEXT
- gauge
- spectrum analysis
- broadband noise

TDR
- Finds cable faults such as short circuit, touch, interruption, branch, bad splice, water ingress, lightning strikes, bruises, etc.
- The maximum verifiable cable length for telecommunication cables is up to 6 km, depending on the wire cross-section.

KE905 Remote Unit
Housing Heavy duty ABS plastic weather-resistant design
Battery cover equipped with captive screws
4 test cord receptacles for alligator-to-TF cords
Resistant Mylar front foil with short operation instructions
Test cords 2 special test cords for testing up to 30 MHz
Insertion loss: 0 to 30 MHz < 0,5 dB
Crosstalk: -78 to -56 dB
Power source 9 V Alkaline battery, typical life 200 h
Overvoltage protection Up to 160 V AC/DC
Dimensions 160 x 95 x 35 mm
Weight 290 g with battery
KECT & KE3700 CT: 31 MHz Line Qualification
General Frequency range: 4,312 kHz up to 31 MHz manual entry or xDSL Bandwith
Input impedance 100 Ω, 120 Ω
Velocity of propagation 0,33 to 3,33 10 mV DC
Cable parameter diameter 0,1 to 1,6 mm
Impedance Output value: 0 ... 1000 Ω, graphical
Resolution / Accuracy: 0,1 Ω / ± 5 % or ± 5 Ω
Return Loss Output value: 0 ... 100 dB, graphical
Resolution / Accuracy: 0,01 dB / ± 1 dB
LCL (Balance) Output value: 0 ... 110 dB, graphical
Resolution / Accuracy at 2 MHz / 10 MHz / 30 MHz: 0,01 dB / ± 0,5 dB / ± 2 dB / ± 5 dB
NEXT Output value: 0 ... 130 dB, graphical
Resolution / Accuracy: 0,01 dB / ± 0,5 dB
Receive Level (high impedance) Output value: -100 ... 10 dBm, graphical
Resolution / Accuracy: 0,01 dBm / ± 1 dBm
Spectrum (high impedance) Output value: -150 ... 10 dBm or -150 ... 10 dBm/Hz, graphical
Resolution / Accuracy: 0,01 dBm / 0,01 dBm/Hz / ± 1 dBm
Wideband Noise Filter: ADSL 1,2 to 1,5 MHz / ADSL 2+ 3,0 MHz / VDSL2 8abcd to 9,0 MHz / VDSL2 12ab to 13,0 MHz / VDSL2 17a to 19,0 MHz / VDSL2 30a to 31,0 MHz
Output value: dBm, numeric
Resolution / Accuracy: 0,01 dBm / ± 1 dBm
Impulse Noise Pulse duration:> 500 µs
Threshold : 0,1 mV to 25,4 mV / -20 to -59,9 dB
Resolution: 0,1 mV / 0,1 dB
Other displayed values: Runtime in seconds / Counter of noise pulses
Measuring time: unlimited
KECT & KE3700 CT: General Information
Connections 2 x 4 mm banana jacks (Line1 and Line2) for 3 pole for TF plug, non-contact protection
RJ45 100 Mb Management Port
Operating temperature 0 °C to +50 °C
Storage temperature -10 °C to +60 °C
Humidity Up to 93%, non-condensing
KECT & KE3700 CT: Line Multimeter
General Overload protection with switching over to voltage measurement
Test lead compensation
Probing between A-B, A-GND and B-GND
Min-Max-Values
DC Voltage Measuring range: 0 to 280 V DC
Resolution / Accuracy up to 6 V: 1 mV DC / ± 0,5 % + 2 digits
Resolution / Accuracy up to 60 V: 10 mV DC / ± 0,5 % + 1 digit
Resolution / Accuracy up to 280 V: 100 mV DC / ± 0,5 % + 1 digit
Overload protection: 300 V DC
DC Current Measuring range: 0 to 700 mA DC
Resolution / Accuracy: 0,1 mA / ±0,5% + 3 digits
Overload protection: 950 mA
AC Voltage Measuring range: 0 to 200 V AC sinusoidal
Resolution / Accuracy up to 6 V: 1 mV DC / ± 1,5 % + 3 digits
Resolution / Accuracy up to 60 V: 10 mV DC / ± 1,5 % + 3 digits
Resolution / Accuracy up to 280 V: 100 mV DC / ± 1,5 % + 3 digits
Overload protection: 300 V AC sinusoidal
AC Frequency Measuring range: 15 Hz to 60 kHz
Resolution / Accuracy up to 600 Hz: 0,01 Hz / ± 0,5 % + 1 digit
Resolution / Accuracy up to 6 kHz: 0,1 Hz / ± 0,5 % + 1 digit
Resolution / Accuracy up to 60 kHz: 1 Hz / ± 0,5 % + 1 digit
AC Current Measuring range: 0 to 500 mA AC
Resolution / Accuracy: 0,1 mA/ ±1,5% + 5 digits
Overload protection: 950 mA
Isolation / Resistance (stress / leakage) Measuring range: 1 kΩ to 50 MΩ at 8 V test voltage / 60 kΩ to 2 (5) GΩ at 100 V test voltage
Resolution / Accuracy up to 30 MΩ: 10 kΩ / ± 2 % + 50 kΩ
Resolution / Accuracy up to 300 MΩ: 100 kΩ / ± 2 % + 500 kΩ
Resolution / Accuracy up to 3 GΩ: 1 MΩ / ± 2 % + 5 MΩ
Resistance Loop Measuring range: 0 to 3 kΩ with DC line voltage suppression
Resolution / Accuracy: 100 mΩ / ±0,5% + 0,5 Ω
Loop length (Short) calculation: 0,1 m to > 20 km depending on cable parameter settings
Loop length resolution / Accuracy: 0,1 m / ±1%
Resistance Measuring range: 0 to 2 MΩ
Resolution / Accuracy: 4 digits / ±1%
Capacitance Measuring range: 0 to 3 µF (10 µF)
Resolution / Accuracy up to 30 nF: 10 pF / ±1% + 100 pF
Resolution / Accuracy up to 300 nF: 100 pF / ±1% + 500 pF
Resolution / Accuracy up to 3 µF: 1 nF / ±1,5% + 5 nF
Opens calculation: 0,1 m to > 20 km depending on cable parameter settings
Opens resolution / Accuracy up to 100 m: 1 mm / ±1%
Opens resolution / Accuracy up to 1 km: 0,1 m / ±1%
Opens resolution / Accuracy > 1 km: 1 m / ±2%
Ground Return Resistance (Station Ground) Measuring range: 0 to 2 MΩ
Resolution / Accuracy: 4 digits / ±1%
LCL Balance @ 1 MHz Measuring range: 0,01 to 90 dB
Resolution / Accuracy: 0,01 dB / ±0,5 dB
NEXT @ 1 MHz Measuring range: 00,1 to 125 dB
Resolution / Accuracy: 0,01 and 0,1 dB / ±0,5 dB
KECT & KE3700 CT: TDR Function
Measuring range 4 m to 6.000 m
Measurement / Display resolutio 6,26 ns or 0,1 m
Pulse width 12,5 ns to 2500 ns
Analog gain 0 dB to 56 dB in 10 dB steps
Zoom max. 10 x

KECT & KE3700 CT

KE3700 CT Data Sheet 1.31 MB

Product Catalogue

Kurth Electronic Program 2019 15.88 MB